Videx VRDK1 (25H) Vandal Resistant One Button Door Entry Kit Technical Manual

This manual introduces a door entry kit from Videx Security Ltd.


Videx VRDK1 (25H) Vandal Resistant One Button Door Entry Kit Technical Manual - cover page
Brand
Videx
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
378 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
A47817589B59AC9D19D63FEA28096D24

About this manual

This technical manual provides step-by-step instructions for installing and commissioning the Videx VRDK1 (25H) vandal-resistant one-button door entry kit. It covers system components, wiring diagrams, connection specifications, and troubleshooting. The kit includes a flush-mounted door panel, audio telephone, and power supply, enabling visitors to call occupants and initiate two-way conversations. The occupant can release an electric lock by pressing a button on the telephone. The manual also includes safety notes, cable sizing guidelines, and maintenance tips for the door panel.

The system requires a 12V AC release or compatible relay for lock operation. Components must be installed according to national electrical standards, and all intercom cables must be routed separately from mains cables. The manual includes a troubleshooting section for common issues such as no speech, lock failure, or hum on the lines.

What's inside

  • Manual Introduction
  • System Introduction
  • System Components
  • Door Panel
  • Power Supply
  • Telephone
  • Installation
  • Cable Size Guide
  • Testing the Installation
  • Panel Care

Specifications

Power Supply ModelArt.520M
DC Outputs12Vdc (200mA), 8Vdc (300mA)
Telephone ModelArt.3021
Lock Release Voltage12V AC
Maximum TelephonesThree

Frequently asked questions

What components are included in the VRDK1 kit?

The kit comprises a flush vandal-resistant door panel, audio telephone, and PSU. The door panel can be converted to surface mount by ordering the VR/SR1N surface back box.

What voltage is required for the lock release?

A 12V AC release should be used with this kit. For gate or other lock releases, a 506N or 506T relay is required.

How do I adjust the speech volume at the door panel?

Speech volume adjustments are carried out at the door panel using a small trimmer driver.

What is the maximum acceptable resistance for the audio system cables?

Maximum acceptable resistance for terminals 1,2 & 6 is 10 Ω and for terminals 3 & 5 is 3 Ω.