About this manual

This TDK-Lambda PXE Series datasheet covers single and dual output DC-DC converters rated 20W to 30W. It lists the key market segments and applications as telecom, datacom and point of load, and states the main features: an industry standard 2" x 1.6" footprint, six sided shielding, agency approvals, and 12V, 24V and 48V inputs. A features and benefits table pairs UL, CSA, EN and CE approvals with easier system approvals, wide range input with fewer parts to inventory, and six sided shielding with reduced radiated noise.

The document then gives a detailed specification table for the PXE20 and PXE30 models, covering output power, voltage accuracy and adjustment, regulation, ripple and noise, remote on/off, temperature ranges, protection, isolation, switching frequency, MTBF, emissions and immunity, safety agency approvals, size and weight. A model selector table lists single and dual output part numbers with output voltage, current, power, input range and efficiency, followed by an outline drawing, PXE20 and PXE30 derating curves, and a pinout table for single and dual outputs.

What's inside

  • Features and Benefits
  • Specifications
  • Model Selector
  • Outline Drawing
  • Derating Curve
  • Pinout
  • Local Distribution

Specifications

Max Output Power20W (PXE20), 30W (PXE30)
Voltage Accuracy±2% (PXE20), ±1% (PXE30)
Operating Temperature-40°C to +85°C
Isolation Voltage1600VDC minimum (Input-Output, Input-Case)
Typical Switching Frequency300kHz (fixed)
Size (L x W x H)50.8 x 40.6 x 10.2 mm
Weight48 g
Warranty2 years

Frequently asked questions

What input voltages does the PXE Series support?

The series offers 12V, 24V and 48V inputs, and the model selector lists the corresponding input ranges for each part number.

What is the operating temperature range of the PXE Series?

The converters operate from -40°C to +85°C, with a maximum case temperature of +100°C.

Which safety agency approvals does the PXE Series carry?

The document lists IEC606950, UL1950, EN60950 and CE Mark (48V input only), together with UL, CSA, EN and CE approvals.

What is the isolation capacitance of the PXE Series?

Maximum isolation capacitance is 300pF for the PXE20 and 1000pF for the PXE30.