TDK-Lambda PXE Series single and dual output 20W to 30W DC-DC converters: features, specifications, model selector, outline drawing and pinout.
This TDK-Lambda PXE Series datasheet covers single and dual output DC-DC converters rated 20W to 30W. It lists the key market segments and applications as telecom, datacom and point of load, and states the main features: an industry standard 2" x 1.6" footprint, six sided shielding, agency approvals, and 12V, 24V and 48V inputs. A features and benefits table pairs UL, CSA, EN and CE approvals with easier system approvals, wide range input with fewer parts to inventory, and six sided shielding with reduced radiated noise.
The document then gives a detailed specification table for the PXE20 and PXE30 models, covering output power, voltage accuracy and adjustment, regulation, ripple and noise, remote on/off, temperature ranges, protection, isolation, switching frequency, MTBF, emissions and immunity, safety agency approvals, size and weight. A model selector table lists single and dual output part numbers with output voltage, current, power, input range and efficiency, followed by an outline drawing, PXE20 and PXE30 derating curves, and a pinout table for single and dual outputs.
| Max Output Power | 20W (PXE20), 30W (PXE30) |
|---|---|
| Voltage Accuracy | ±2% (PXE20), ±1% (PXE30) |
| Operating Temperature | -40°C to +85°C |
| Isolation Voltage | 1600VDC minimum (Input-Output, Input-Case) |
| Typical Switching Frequency | 300kHz (fixed) |
| Size (L x W x H) | 50.8 x 40.6 x 10.2 mm |
| Weight | 48 g |
| Warranty | 2 years |
The series offers 12V, 24V and 48V inputs, and the model selector lists the corresponding input ranges for each part number.
The converters operate from -40°C to +85°C, with a maximum case temperature of +100°C.
The document lists IEC606950, UL1950, EN60950 and CE Mark (48V input only), together with UL, CSA, EN and CE approvals.
Maximum isolation capacitance is 300pF for the PXE20 and 1000pF for the PXE30.