Safety and installation guidelines for TDK-Lambda HFE2500-S1U rack-mounted power supplies, including environmental, electrical, and mounting requirements.
This manual provides safety and installation instructions for TDK-Lambda’s HFE2500-S1U rack-mounted power supplies. It covers critical safety warnings, environmental and electrical specifications, and rack mounting guidelines. The unit must be installed by qualified personnel and earthed properly. It is not intended for end-user use and must comply with EMC and safety standards. The manual also details output and input parameters, temperature derating, and remote control options.
The HFE2500-S1U is designed for industrial applications in Pollution Degree 2, overvoltage category II environments. It requires proper ventilation, secure mounting, and specific earthing. The unit contains hazardous energy and must be protected from user access to output terminals. Special attention is required for rack installation to avoid overheating, mechanical stress, or circuit overloading.
| Maximum Output Power | Refer to HFE2500 specifications |
|---|---|
| Maximum Output Current | 320A per output (Total 640A) |
| Input Voltage Range | 85~265Vac continuous, 47~63Hz |
| Operating Temperature | 10~50°C: 100% load. +50°C to +60°C: Derate 2%/°C of load |
| Withstand Voltage (Input-Output) | 3000Vrms, 1min |
| Safety Standards | IEC 62368-1, UL62368-1, CSA22.2 No.62368-1, EN62368-1 |
No, it is designed as a component power supply and must be installed within other equipment by qualified personnel.
320A per output, totaling 640A for dual outputs.
It complies with IEC 62368-1, UL62368-1, CSA22.2 No.62368-1, and EN62368-1.