This manual provides installation, operation, maintenance, and troubleshooting instructions for the Swagelok E industrial pressure sensor.
The Swagelok E industrial pressure sensor is designed for electronic monitoring of system pressure in various industrial applications. It features temperature compensation to ensure accuracy and long-term stability in environments with temperature fluctuations. The sensor is available with various pressure connections, rated pressures, and signal outputs to meet diverse application needs. This manual is written in Chinese.
| Accuracy (Best Fit Line) | 0.25 % of span |
|---|---|
| Accuracy (Limit Point) | 0.5 % of span |
| Max Power Supply Voltage | 30 V dc |
| Max Load Current (2-wire) | 100 mA |
| Max Ambient Temperature (T6) | 60°C |
| Max Ambient Temperature (T4) | 105°C |
The sensor must be installed, used, and maintained according to NEC, local codes, and this manual to prevent serious injury or loss.
The maximum allowable power supply voltage is 30 V dc.
You must release system pressure and purge the sensor before performing any maintenance.
System designers and users are responsible for ensuring safe, fault-free performance through proper selection, installation, and maintenance.