Swagelok B-283–B-288 High Pressure Needle Valve Manual

This document introduces the features and characteristics of high pressure needle valves, including the maximum working pressure, maximum working temperature, leak detection function, bottom gasket structure, non-rotating stem design, end connection method, etc.


Swagelok B-283–B-288 High Pressure Needle Valve Manual - cover page
Brand
Swagelok
Category
Industrial Supply
Document type
Product Leaflet
Language
Japanese
Pages
7
File format
PDF
File size
570 KB
Published
16 November, 2011
Updated
30 September, 2023
MD5 checksum
8D9C40F3001E14801323DAFB6F95ADAD

About this manual

This document provides specifications, material options, and connection details for Swagelok high‑pressure needle valves in the B‑283 to B‑288 series. It includes maximum operating pressure and temperature, stem material choices, and optional Grafoil packing for high‑temperature service.

Additional sections cover air‑actuated valve configurations, accessory kits, and ordering instructions for stem, packing, and handle options. Safety and installation notes are also included. This manual is written in Japanese.

What's inside

  • High Pressure Needle Valve B‑283
  • B‑284 Needle Valve Metering Valve
  • B‑285 Valve Details
  • B‑286 Options and Accessories
  • Air‑Actuated Valve
  • B‑287 Dual‑Acting Valve
  • B‑288 Fittings and Connectors
  • Document Information

Specifications

Maximum operating pressure310.0 MPa
Maximum operating temperature232 °C
End connection typesHigh‑pressure parallel thread, NPT thread
Standard stem material440C stainless steel
Optional Grafoil stem packing temperature limit454 °C
Torque required to close at max pressure5.7 N·m

Frequently asked questions

What is the maximum operating pressure for the B‑283 valve?

The B‑283 valve is rated for a maximum operating pressure of 310.0 MPa.

How much torque is needed to close the valve at its maximum pressure?

A torque of about 5.7 N·m is required to close the valve at the maximum pressure.

Can the stem packing be used at temperatures above 400 °C?

Yes, the optional Grafoil stem packing is rated for use up to 454 °C.

What end‑connection options are available for these valves?

The valves are offered with high‑pressure parallel threads and NPT threads as end connections.