User manual for the Sunstar GH-903 infrared line detector, covering safety, power requirements, wiring and operation.
SUNSTAR GH-903 is a PIR infrared detector that outputs an alarm signal when a person moves within its receiving range; it is intended for security applications such as banks, warehouses, and homes. The manual describes indoor installation above 2 m, wiring, pulse-count selection, terminal functions, detection range, and technical specifications.
Power is 9-16 V DC. After correct wiring and cover installation, the indicator lights and then turns off after 1-2 minutes to indicate normal detection; a person entering the detection area triggers the alarm output and indicator. The detector uses a normally closed relay output and a normally closed tamper switch, with a 12 m x 12 m detection range and 5-year warranty under normal use excluding human damage. This manual is written in Chinese.
| Working voltage | 9-16 V DC |
|---|---|
| Alarm relay output | Normally closed dry contact; max switching 50 V DC, 80 mA |
| High-frequency interference immunity | 10-1000 MHz |
It works on 9-16 V DC.
It requires 9-16VDC operating voltage.