Stromag SH1 Hydraulic Disc Brake Product Leaflet

Stromag SH1 hydraulic disc brake leaflet covering features, working conditions, options and technical data.


Stromag SH1 Hydraulic Disc Brake Product Leaflet - cover page
Brand
Stromag
Category
Other products
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
412 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
95406193E816D8839BF1008B21A4D542

About this manual

Stromag SH1 is described as the smallest and most compact emergency brake in the SH range, for disc diameters from 300 to 1000 mm. It is intended for handling equipment such as cranes, conveyors and winches in steel, mining, mass transport, port and offshore applications, with fail-safe hydraulic release and a design rated for 200,000 cycles.

The leaflet lists working conditions, use restrictions, options such as opening and wear switches, and technical data including braking forces, pressures, dimensions and electrical data for the inductive switches.

What's inside

  • Applications
  • Benefits include
  • Working conditions
  • Use
  • Options
  • TECHNICAL DATA / DIMENSIONS
  • Electrical data

Specifications

Disc diameter300 to 1000 mm
Weight35 kg
Dynamic braking temperature range-30°C to +70°C
Parking temperature range-40°C to +70°C
Relative humidity≤ 70%
Dust in atmosphere≥ 65μm
Associated disc thicknesses12.7, 15, 20 and 30 mm
ProtectionC5-M M
Dynamic braking force (ES3-7 / US2-1)11,000 N / 11,000 N
Static braking force (ES3-7 / US2-1)9,900 N / 9,680 N
Linear speed of disc≤ 50 m/s
Dynamic braking torqueBT = BF (D/2,000-0.037)
Regulation pressure (minimum)150 bar
Regulation pressure (maximum)170 bar
Setting pressure limit valve190 bar
Electrical switches3-wire PNP NO, 12 to 24 VDC, 200 mA
New lining thickness8 mm
Lining thickness to wear6 mm
Design life200,000 cycles

Frequently asked questions

What disc diameters can the SH1 brake be used with?

It can be associated with disc diameters from 300 to 1000 mm.

What is the dynamic braking temperature range?

Dynamic braking is rated from -30°C to +70°C.

What is the parking temperature range?

With the brake applied for parking, the range is -40°C to +70°C.

When should the brake be applied?

It should be applied only in case of emergency stop, overspeed or shutdown of electric mains.