Solarbio BC2495 Blood Glucose Content Assay Kit (Micro Method) Manual

Solarbio BC2495 blood glucose content assay kit (micro method) for detecting glucose in mammalian blood; includes reagent preparation, procedure, and…


Solarbio BC2495 Blood Glucose Content Assay Kit (Micro Method) Manual - cover page
Brand
Solarbio
Category
Chemical products
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
653 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
978CD90209913C032C54EF0930D3794D

About this manual

Solarbio BC2495 is a blood glucose content assay kit (micro method) for detecting glucose in mammalian blood. The kit contains three liquid reagents, 10 mL each, stored at 4°C, and uses a glucose oxidase colorimetric method with absorbance measured at 505 nm.

Before use, reagent 1 is a 2 μmol/mL glucose solution and the mixed reagent is prepared by combining reagents 2 and 3 in equal volumes. The procedure includes sample handling, incubation at 37°C for mammals or 25°C for other species for 15 minutes, and calculation using A1, A2, and A3. The kit has a minimum detection limit of 0.0188 μmol/mL and a linear range of 0.125-8 μmol/mL. This manual is written in Chinese.

What's inside

  • Product composition
  • Reagent preparation
  • Product description
  • Technical specifications
  • Required instruments and supplies
  • Operating procedure
  • Precautions
  • Related published literature
  • References
  • Related products

Specifications

Kit size100T/96S
Minimum detection limit0.0188 μmol/mL
Linear range0.125-8 μmol/mL
Detection wavelength505 nm
Incubation37°C (mammals) or 25°C (other species), 15 min

Frequently asked questions

What is the detection principle of the BC2495 kit?

Glucose oxidase catalyzes glucose to gluconic acid and hydrogen peroxide; peroxidase then catalyzes hydrogen peroxide to oxidize 4-aminoantipyrine coupled with phenol, forming a colored compound with characteristic absorbance at 505 nm.

How is blood glucose content calculated?

Blood glucose content (μmol/mL) = 2 μmol/mL × (A3 - A1) ÷ (A2 - A1), where A1, A2, and A3 are the absorbances of the blank, standard, and sample tubes.

What should be done if a sample absorbance is greater than 1.2?

Dilute the sample with distilled water before measurement.

How are the reagents prepared before use?

Reagent 1 is a 2 μmol/mL glucose solution; the mixed reagent is prepared by mixing reagents 2 and 3 in equal volumes immediately before use.