Solarbio YA2551 CM Sepharose 6FF Prepacked Column Instructions

CM Sepharose 6FF is a weak cation exchange resin that is widely used for the separation and purification of downstream proteins, nucleic acids and peptides in biopharma and bioengineering.


Solarbio YA2551 CM Sepharose 6FF Prepacked Column Instructions - cover page
Brand
Solarbio
Category
Chemical products
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
285 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
11C4BE6C81AA4D5E8E0D12B47375D2B3

About this manual

This is the instruction sheet for the Solarbio CM Sepharose 6FF prepacked column, catalog number YA2551, supplied in formats from 1×1 mL to 5×5 mL and stored at 2-8 °C. The medium is a weak cation exchanger with -O-CH2COO- groups on highly crosslinked 6% agarose beads, intended for laboratory and industrial-scale purification of proteins, nucleic acids and peptides.

The document lists the medium performance parameters and then walks through the purification process: buffer and sample preparation, washing, equilibration, loading, washing of impurities and elution on a low-to-medium pressure chromatography system such as AKTA. It also covers SDS-PAGE checking of the collected fractions, cleaning of the resin after use, and a short troubleshooting table of common problems. This manual is written in Chinese.

What's inside

  • 产品说明
  • 表 1:介质性能参数
  • Buffer 的准备
  • 样品准备
  • 样品纯化
  • SDS-PAGE 检测
  • 填料清洗
  • 常见问题

Specifications

MatrixHighly crosslinked 6% agarose beads
Ion exchange typeWeak cation
Ion capacityapprox. 0.09-0.13 mmol H+/mL medium
Particle size45-165 μm
Recommended flow rate300-600 cm/h
pH stability range4-13
Storage buffer20% ethanol
Available sizes1*1mL / 1*5mL / 5*1mL / 3*1mL+1*5mL / 5*5mL

Frequently asked questions

What kind of chromatography medium is CM Sepharose 6FF?

It is a weak cation exchange resin whose ion exchange group is -O-CH2COO-, made on highly crosslinked 6% agarose beads.

How should the prepacked column and medium be stored?

Equilibrate the medium in 20% ethanol and keep it at 2-8 °C; the 20% ethanol prevents microbial growth.

How is the resin cleaned after hydrophobic non-specific adsorption?

Wash with 3-4 column volumes of 70% ethanol or 1% Triton X-100, then immediately with 5 column volumes of PBS, pH 7.4.

What can be done if the column back pressure is too high?

The table lists blocked packing as the cause and recommends cleaning the resin; samples should be filtered (0.22 or 0.45 μm) or centrifuged before loading.

Download PDF (285 KB)

More Solarbio Manuals


View all Solarbio manuals →