Instruction manual for SMC ZSM1-115/ZSM1-121 vacuum switches covering safety, specifications, installation, wiring, and maintenance.
The manual provides safety instructions, specifications, and installation guidelines for the ZSM1-115 and ZSM1-121 vacuum switches used to control vacuum line pressure via electric signals.
It details electrical specifications, wiring, pressure setting adjustment, maintenance procedures, and disposal information, with contact details for SMC Corporation.
| Model | ZSM1-115, ZSM1-121 |
|---|---|
| Switch specifications | Solid State Contact (reed switch) |
| Fluid | Air/Inert Gas |
| Max. operating pressure | 0.5 MPa |
| Regulating pressure range | -27 to -80 kPa |
| Hysteresis (ZSM1-115) | Max. 15 kPa |
| Hysteresis (ZSM1-121) | Max. 20 kPa |
| Repeatability | ±10% or less |
| Ambient and fluid temperature | -5 to 60°C (no freezing) |
| Supply Voltage (ZSM1-115) | 4.5 to 28 VDC |
| Supply Voltage (ZSM1-121) | 100 VAC/DC (or less) |
| Indicator Light | ON: When output is ON |
| Lead Wires (ZSM1-115) | 3 |
| Port size | R1/8 |
| Weight | 65g |
| ZSM1-115 Output (open collector) | 28 V: Max. 40 mA |
| ZSM1-115 Current consumption | 10 mA or less (24 VDC) |
| ZSM1-121 Maximum operating current | 24 V or less: Max. 50 mA, 48 V: Max. 40 mA, 100 V: Max. 20 mA |
| ZSM1-121 Max. contact capacity | AC 2 VA, DC 2 W |
| Specified tightening torque (R1/8) | 3~5 N·m |
| Pressure setting adjustment turns | 0 to 18 turns |
The regulating pressure range is -27 to -80 kPa.
The supply voltage for ZSM1-115 is 4.5 to 28 VDC.
The specified tightening torque for R1/8 is 3~5 N·m.
The pressure setting adjustment allows between 0 and 18 turns.