SMC ZK2 series vacuum unit ejector/vacuum pump system instruction manual with safety instructions and specifications.
This instruction manual covers the SMC ZK2 series vacuum unit, an ejector/vacuum pump system whose intended use is to generate vacuum and control the operation of suction and release. It opens with safety instructions that explain the Caution, Warning and Danger hazard levels and require work to be carried out in a safe manner by a qualified person in compliance with applicable national regulations.
The rest of the document lists specifications: general specifications such as ambient temperature range, fluid and vibration/impact resistance; valve specifications including actuation type, operating pressure range and rated voltage; noise levels by model; ejector specifications such as nozzle diameter, suction flow and vacuum pressure; and the specifications of the suction filter, pressure sensor and pressure switches for vacuum.
| Ambient temperature range | -5 to 50 °C (without pressure sensor and pressure switch, with pressure switch); 0 to 50 °C (with pressure sensor); 5 to 50 °C (with pressure switch with energy saving function); no condensation |
|---|---|
| Fluid | Air |
| Valve operating pressure range | 0.3 to 0.6 MPa |
| Rated voltage | 24 VDC (ZK2-VA□□5□□); 12 VDC (ZK2-VA□□6□□) |
| Power consumption | 0.35 W (ZK2-VA□□□□); 0.4 W (ZK2-VA□□□□A) |
| Nozzle diameter | 0.7 mm (ZK2□07), 1.0 mm (ZK2□10), 1.2 mm (ZK2□12), 1.5 mm (ZK2□15) |
| Max. vacuum pressure | -91 kPa |
| Suction filter filtration rating | 30 μm |
| Suction filter filtration area | 510 mm2 |
| Vibration resistance | 30 m/s2 (without pressure sensor and pressure switch, with pressure sensor); 20 m/s2 (with pressure switch) |
| Impact resistance | 150 m/s2 (without pressure sensor and pressure switch, with pressure sensor); 100 m/s2 (with pressure switch); 50 m/s2 for valve type R |
The vacuum unit is intended to generate vacuum and control the operation of suction and release.
Air is the specified fluid.
The valve operating pressure range is 0.3 to 0.6 MPa.
The suction filter has a filtration rating of 30 μm and a filtration area of 510 mm2.