SMC ZK2 Vacuum Unit Ejector/Vacuum Pump System Instruction Manual

SMC ZK2 series vacuum unit ejector/vacuum pump system instruction manual with safety instructions and specifications.


SMC ZK2 Vacuum Unit Ejector/Vacuum Pump System Instruction Manual - cover page
Brand
SMC
Category
Automation control Equipment
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
434 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1992DCDCC2F713DBD039472A16A57BB6

About this manual

This instruction manual covers the SMC ZK2 series vacuum unit, an ejector/vacuum pump system whose intended use is to generate vacuum and control the operation of suction and release. It opens with safety instructions that explain the Caution, Warning and Danger hazard levels and require work to be carried out in a safe manner by a qualified person in compliance with applicable national regulations.

The rest of the document lists specifications: general specifications such as ambient temperature range, fluid and vibration/impact resistance; valve specifications including actuation type, operating pressure range and rated voltage; noise levels by model; ejector specifications such as nozzle diameter, suction flow and vacuum pressure; and the specifications of the suction filter, pressure sensor and pressure switches for vacuum.

What's inside

  • Safety Instructions
  • General Specifications
  • Valve Specifications
  • Noise Level (Reference values)
  • Ejector Specification
  • Suction Filter
  • Pressure Sensor
  • Pressure Switch for Vacuum
  • Pressure Switch for Vacuum with energy saving function

Specifications

Ambient temperature range-5 to 50 °C (without pressure sensor and pressure switch, with pressure switch); 0 to 50 °C (with pressure sensor); 5 to 50 °C (with pressure switch with energy saving function); no condensation
FluidAir
Valve operating pressure range0.3 to 0.6 MPa
Rated voltage24 VDC (ZK2-VA□□5□□); 12 VDC (ZK2-VA□□6□□)
Power consumption0.35 W (ZK2-VA□□□□); 0.4 W (ZK2-VA□□□□A)
Nozzle diameter0.7 mm (ZK2□07), 1.0 mm (ZK2□10), 1.2 mm (ZK2□12), 1.5 mm (ZK2□15)
Max. vacuum pressure-91 kPa
Suction filter filtration rating30 μm
Suction filter filtration area510 mm2
Vibration resistance30 m/s2 (without pressure sensor and pressure switch, with pressure sensor); 20 m/s2 (with pressure switch)
Impact resistance150 m/s2 (without pressure sensor and pressure switch, with pressure sensor); 100 m/s2 (with pressure switch); 50 m/s2 for valve type R

Frequently asked questions

What is the intended use of the ZK2 vacuum unit?

The vacuum unit is intended to generate vacuum and control the operation of suction and release.

What fluid is used with the vacuum unit?

Air is the specified fluid.

What is the operating pressure range of the ZK2 valves?

The valve operating pressure range is 0.3 to 0.6 MPa.

What is the filtration rating of the suction filter?

The suction filter has a filtration rating of 30 μm and a filtration area of 510 mm2.

Download PDF (434 KB)

More SMC Manuals


View all SMC manuals →