SMC PSE53 Pressure Sensor User Manual

This manual provides installation, wiring, and maintenance instructions for the SMC PSE53 pressure sensor.


SMC PSE53 Pressure Sensor User Manual - cover page
Brand
SMC
Document type
User Manual
Language
Chinese
Pages
16
File format
PDF
File size
509 KB
Published
20 October, 2026
Updated
20 October, 2026
MD5 checksum
D1B74C9E952AAE8CBBD63BC21484D2FC

About this manual

The document is a user manual for the SMC PSE53 series pressure sensors. It outlines safety precautions, including warnings against using flammable gases or operating in explosive environments due to the lack of explosion-proof construction. The guide specifies that only qualified personnel should perform assembly and maintenance after ensuring power and air sources are disconnected. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Model Representation
  • Terminology Definition
  • Installation & Setup
  • Wiring Methods
  • Troubleshooting Table
  • Specifications

Frequently asked questions

What is the maximum pulling force allowed on the pressure sensor's wires?

The maximum pulling force allowed on the wires is 23N.

What is the maximum recommended length for the sensor's wiring?

The wiring should be kept to a maximum length of 10 meters.

What is the recommended minimum bending radius for the sensor's wiring?

The recommended bending radius is 6 times the wire outer diameter or 33 times the insulation outer diameter, whichever is larger.