Instruction manual for the SMC ITV*0*0-CC**** Series electro-pneumatic regulator, covering safety, specifications, installation, wiring, settings and…
Instruction Manual ITV2-TF2Z351EN covers the SMC ITV*0*0-CC**** Series electro-pneumatic regulator for CC-Link. It states that the intended use is to control the flow and pressure of fluid while connected to CC-Link communication.
This two-page document presents safety instructions, general, size/weight and communication specifications, installation, wiring, LED display, DIP switch settings, communication data allocation, maintenance, limitations of use, disposal and contact information. It includes tables for the power supply and communication connectors and for CC-Link input/output data allocation.
| Protocol | CC-Link Ver 1.10 |
|---|---|
| Station type | Remote device |
| Device type | Analogue I/O |
| Occupied stations | 1 Station |
| Communication rate | 10 M / 5 M / 2.5 M / 625 k / 156 k bps |
| Node address | 1 to 64 |
| Occupied area (Input/output data) | 4 word / 4 word (32 bit / 32 bit) |
| Communication data resolution | 12 bit (4096 resolution) |
| Supply voltage | 24 VDC ± 10% |
| Current consumption | 0.16 A or less |
| Enclosure rating | IP65 |
| Ambient and fluid temperature | 0 to 50°C (no condensation) |
It is intended to control the flow and pressure of fluid while connected to CC-Link communication.
The communication specifications list CC-Link Ver 1.10.
The node address is set by DIP switch, with a range of 1 to 64.
It requires 24 VDC ± 10%, with current consumption of 0.16 A or less.