EU-Type Examination Certificate FM13ATEX0082X for Sierra Instruments 640i and 780i insertion and in-line thermal mass flowmeters, with conditions of use.
This is EU-Type Examination Certificate No. FM13ATEX0082X, issued by FM Approvals Europe Ltd. and dated 11 August 2021, for the 640i and 780i Insertion and In-line Thermal Mass Flowmeters made by Sierra Instruments Inc. of Monterey, California. It certifies that the equipment complies with the Essential Health and Safety Requirements of Directive 2014/34/EU for equipment used in potentially explosive atmospheres, following assessment against EN/IEC 60079-0:2018, EN 60079-1:2014, EN 60079-31:2014 and EN 60529:1991+A1:2000+A2:2013.
The schedule describes the flowmeters: they measure gas flow, integrate configuration, validation and diagnostics in a probe-mounted or remotely mounted housing, and can provide 4-20 mA flow and temperature output, alarm output and an optional pressure output. The 640i is for insertion into pipes or ducts from three inches up to 72 inches, while the 780i goes in-line to 8-inch flow bodies. The document also gives the marking, the specific conditions of use, the test and assessment procedure and the certificate history from the original 2014 issue through Supplement 8.
| Ambient temperature range | -20°C to +60°C |
|---|---|
| Process temperature range | -40°C to +200°C |
| Pressure | 300 psi (in-line) or 500 psi (insertion) |
| Ingress protection rating | IP66 |
| Power supply | 24 Vdc or 100-240 Vac |
| Flow and temperature output | 4-20 mA |
| Remote mounting distance | Up to 200 feet |
| 640i insertion pipe or duct size | Three inches up to 72 inches |
| 780i in-line flow body size | Up to 8-inch flow bodies |
The EU-Type Examination Certificate number is FM13ATEX0082X, issued by FM Approvals Europe Ltd.
The marking must include II 2 G Ex db IIC T3 Gb Ta = -20°C to +60°C and II 2 D Ex tb IIIC T200°C Db Ta = -20°C to +60°C.
The flameproof joints are not intended to be repaired, and a suitably certified conduit sealing device is required within 13 inches of the enclosure for probes longer than 13 inches.
Compliance was assessed against EN/IEC 60079-0:2018, EN 60079-1:2014, EN 60079-31:2014 and EN 60529:1991+A1:2000+A2:2013.