About this manual

The Siemens Somatom Emotion 16 is a 16-slice CT scanner manufactured in 2010, currently installed in a showroom in Frankfurt, Germany. The document provides detailed technical specifications for the gantry, detector, image reconstruction, tube assembly, patient table, and installation requirements.

Key specifications include a 70 cm gantry aperture, 16 detector rows with 17,664 elements, rotation times of 0.6, 1.0, and 1.5 seconds, and a DURA 422MV tube with 80/110/130 kV voltage options. The system supports reconstructed slice widths from 0.6 to 10 mm, a maximum scan length of 150 cm, and a patient table load of 200 kg. Installation requires 18 m², 380–480 V power supply, and a maximum power connection of 70 kVA.

What's inside

  • SYSTEM
  • GANTRY
  • DETECTOR
  • IMAGE RECONSTRUCTION
  • TUBE ASSEMBLY
  • PATIENT TABLE
  • INSTALLATION
  • INCLUDED SPECIFICATIONS

Specifications

Year of Manufacture2010
Gantry Aperture70 cm
Scan Field50 cm
Gantry Tilt+/- 30°
Rotation Times0.6, 1.0, 1.5 s
Detector Rows16
Detector Elements17,664
Channels per Slice1,472
Max ProjectionsUp to 1,250 (1/360°)
Max Slices per Rotation16
Reconstruction Timeup to 8 images/s
Reconstructed Slice Widths0.6, 0.75, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 mm
Slice Increment0.1–10 mm
Pitch Factor (Volume Pitch)0.4–1.8
Max Spiral Scan Time100 s
Max Scan Length150 cm
Tube ModelDURA 422MV
Tube Current Range20–345 mA
Tube Voltages80, 110, 130 kV
Anode Heat Storage5.0 MHU
Focal Spot Size0.8 x 0.5 mm/7° and 0.8 x 0.7 mm/7°
Max Table Load200 kg
Table Speed1–100 mm/s
Vertical Table Travel Range45–83 cm
Vertical Travel Speed<22.4 mm/s
Scanable Range (metal-free)153 cm
Examination Room Temperature Range18–30° C
Gantry Heat Dissipationmax. 6.8 kW
Installation Surface Area18 m²
Power Supply380–480 V
Nominal Line Frequency50; 60 Hz
Max Power Connection<70 kVA
Power Consumption Standby<3.7 kW
Power Consumption Scanning<7.0 kW

Frequently asked questions

What is the gantry aperture of the Siemens Somatom Emotion 16?

The gantry aperture is 70 cm.

What tube voltage options are available on the Somatom Emotion 16?

The tube voltages are 80, 110, and 130 kV.

What is the maximum patient table load?

The maximum table load is 200 kg.