This application note explains how to calculate dewpoint temperature from relative humidity and temperature using Sensirion SHTxx sensors.
The document provides a formula to compute dewpoint temperature from relative humidity and temperature measurements. It includes the theoretical background, a simplified calculation method, and example calculations for different humidity and temperature conditions.
The note also shows the deviation of the simplified formula from actual values across a temperature range of -40°C to 100°C, illustrated in Figure 1. References to the original meteorological handbook and a more complex calculation method are provided for further study.
The dewpoint is calculated using the saturation vapor pressure over water (EW) multiplied by relative humidity, then applying a logarithmic formula to derive the dewpoint temperature in Celsius.
The simplified formula's deviation from actual values is shown in Figure 1 for temperatures between -40°C and 100°C.