Schneider Electric Harmony GTU user manual covering box and display modules, specifications, dimensions, installation, wiring, and maintenance.
Schneider Electric Harmony GTU User Manual (document EIO0000001735, 11/2019) covers the Harmony GTU box and display modules. It includes safety information, part numbers, package contents, certifications, dimensions, installation and wiring, and maintenance.
The manual also provides electrical, environmental, structural, functional, and interface specifications, plus procedures for SD/CFast card handling, USB covers, isolation units, cleaning, battery replacement, and backlight service notes.
| Rated Input Voltage | 12 Vdc (supply from Display Module) |
|---|---|
| Maximum Power Consumption | HMIG2U 17.5 W; HMIG3U 25 W; HMIG5U 35 W; HMIG5U2 25 W |
| Power Consumption Without External Devices | HMIG2U 8.8 W or less; HMIG3U 12.5 W or less; HMIG5U 22.5 W or less; HMIG5U2 15 W or less |
The rated input voltage is 12 Vdc, supplied from the Display Module.
The HMIG5U has a maximum power consumption of 35 W.
No, the backlight is not user replaceable; contact your local distributor when replacement is required.
Wait at least 10 seconds after power has been turned off.