The Schmersal RSS 36-I2-D-R is an electronic safety sensor with RFID coding for monitoring movable guard doors. It features individual coding with multiple teach-in, a locking force of approximately 18 N, and series diagnostics capability. The sensor is designed for use in safety circuits up to PL e and SIL 3.

The manual covers installation, electrical connection, commissioning, maintenance, and disposal. Technical specifications include a maximum response time of 100 ms, switching distances of 10 mm (ON) and 16 mm (OFF), IP65/IP67/IP69 protection, and an operating temperature range of -28 °C to +70 °C. The sensor connects via an 8-pin M12 cable and supports series connection of up to 31 devices. This manual is written in Chinese.

What's inside

  • About this document
  • Product description
  • Technical data
  • Installation
  • Electrical connection
  • Actuator coding
  • Operating principle and diagnostic functions
  • Commissioning and maintenance
  • Removal and disposal

Specifications

StandardsEN ISO 13849-1, EN IEC 60947-5-3, EN IEC 61508
CodingIndividual coding, multiple teach-in
Coding level (EN ISO 14119)High
Operating principleRFID
RFID frequency125 kHz
Maximum response time100 ms
Maximum risk time200 ms
Locking forceApproximately 18 N
Assured switching distance ON (Sao)10 mm
Assured switching distance OFF (Sar)16 mm
Protection classIP65, IP67, IP69
Operating temperature-28 ... +70 °C
Supply voltage24 VDC -15% / +10%
Safety outputs2 fail-safe digital outputs
Safety output current max0.25 A
PFH value2.70 x 10⁻¹⁰ /h
Safety integrity level (SIL)3
Mission time20 years
Mechanical life1,000,000 operations
Cable length2 m
ConnectorM12, 8-pin

Frequently asked questions

What is the locking force of the RSS 36-I2-D-R safety sensor?

The locking force is approximately 18 N.

What is the maximum response time of the sensor?

The maximum response time is 100 ms.

What protection classes does the sensor have?

The sensor has IP65, IP67, and IP69 protection.

What is the operating voltage range?

The operating voltage is 24 VDC with -15% to +10% tolerance.