Red Lion CUB5I Miniature 5-Digit DC Current Meter Manual

The Red Lion CUB5I is a miniature 5-digit DC current meter with four selectable ranges and optional setpoint, serial, or USB cards.


Red Lion CUB5I Miniature 5-Digit DC Current Meter Manual - cover page
Brand
Redlion
Category
panel
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
1.3 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
26AB201848FABE9C7F1B0260D49455AD

About this manual

The Red Lion CUB5I is a miniature electronic 5-digit DC current meter. It accepts a DC current input and offers four selectable ranges: 200 µA, 2 mA, 20 mA, and 200 mA, selected with a programming jumper and software input range selection. The display uses a 5-digit LCD with 0.48 in (12.2 mm) high digits and is available in reflective or red/green backlight versions.

Features include minimum and maximum display capture, display offset, a units indicator, and a programmable user input. The meter operates from 9 to 28 VDC and can be expanded with optional setpoint output, RS232/RS485 serial, and USB programming cards. The front bezel meets NEMA 4X/IP65 requirements when properly installed.

What's inside

  • General Description
  • Safety Summary
  • Dimensions
  • General Meter Specification
  • Ordering Information
  • Optional Plug-in Cards
  • Installing the Meter
  • Setting the Jumpers
  • Input Range Jumper
  • Remove/Replace the Rear Cover

Specifications

Display5-digit LCD, 0.48 in (12.2 mm) high digits
Power+9 to +28 VDC
Input ranges200 µA, 2 mA, 20 mA, and 200 mA
Accuracy0.1% of span at 23 °C, less than 85% RH
Response timeDisplay 500 ms minimum; output 800 ms maximum with input filter at 0
Operating temperature-35 to 75 °C for CUB5IR00
Weight3.2 oz (100 g)
Enclosure ratingIP65 face only
MemoryNonvolatile E2PROM retains programming parameters and max/min values
User inputProgrammable input with internal 10K Ω pull-up to +9 to 28 VDC

Frequently asked questions

What DC current input ranges does the Red Lion CUB5I support?

It supports 200 µA, 2 mA, 20 mA, and 200 mA DC current ranges.

What power source does the CUB5I require?

The input voltage range is +9 to +28 VDC.

How is the input range selected on the CUB5I?

The range is selected with a programming jumper and software input range selection, and the programmed range must match the jumper setting.

What are the CUB5I display versions?

CUB5IR00 is a reflective LCD; CUB5IB00 is a transmissive LCD with selectable red or green LED backlight.

Download PDF (1.3 MB)