Installation, operation and maintenance manual for Pulsafeeder Eclipse E02, E05, E12, E25, E75 and E125 external gear metering pumps.
This manual covers the Pulsafeeder Eclipse Series external gear metering pumps in models E02, E05, E12, E25, E75 and E125. It provides installation, operation and maintenance information, including ATEX requirements, disassembly/assembly procedures for non-metallic and metallic pumps, parts diagrams and lists, inspection and wear limits, troubleshooting, specifications, dimensional drawings and performance curves.
According to the manual, Eclipse pumps use a magnetic drive coupling to handle hazardous, highly corrosive, explosive or toxic chemicals without mechanical seals or packing. The pumps mount to standard NEMA 56C, 143/145TC and 182/184TC motors and IEC 63, 80, 100 and 112 B3/B14 C-face motors; the manual warns not to let the pump run dry.
| Pump type | External gear metering pump |
|---|---|
| Drive coupling | Magnetic drive coupling |
| NEMA motor mounting | NEMA 56C, 143/145TC and 182/184TC |
| IEC motor mounting | IEC 63, 80, 100 and 112 B3/B14 metric flanged C-face |
| Maximum decoupled magnet temperature | 450 °F (232 °C) |
The manual covers Eclipse models E02, E05, E12, E25, E75 and E125.
Pulsafeeder warrants Eclipse products for one year from the date of shipment from its factory in Rochester, New York, USA.
No. The manual states it is not recommended to allow the pump to run dry because this can cause excessive pump wear or failure.
The magnetic coupling can decouple if the coupling torque limit is exceeded, for example if foreign material jams the pump gears.