Installation, wiring and programming instructions for the MS SEDCO SAMv0318 Secondary Activation Module used on Knowing Act automatic swing doors.
This four-page document gives installation and programming instructions for the MS SEDCO SAMv0318 Secondary Activation Module (SAM), a microprocessor-based timing module for "Knowing Act" automatic swing doors such as those in hospital corridors. The SAM controls the push plate wall switch, the approach sensor (secondary activation) and the presence sensor (swing side safety), and it monitors the door's open-to-closed positions and closing time through the operator motor.
The text covers a general description, basic installation steps, layout and wiring connections for electromechanical and electrohydraulic operators, the operating display key with the full programming sequence (relay lockout time d1, presence sensor, push plate, output 1, approach sensor, electrohydraulic mode and auto program mode), technical data and a one-year warranty.
| Input Power | 12-24V AC or DC |
|---|---|
| Power Consumption | <1W (0.050 Amps @ 12V) |
| Output Contacts | Form C, rated at 3 Amps |
| Temperature Rating | -22°F to 158°F (-30°C to 70°C) |
| Weight | Less than 0.25 lbs |
| Physical Size | 4.75"L x 2.125"W x 0.75"H |
| Factory relay lockout time (d1) | 3.0 seconds |
It operates on 12-24V AC or DC and consumes less than 1W (0.050 Amps at 12V).
Install the 10K resistor only if the motor voltage exceeds 50V AC, such as 115VAC; do not use it with low AC or DC voltage.
MS SEDCO guarantees the product against manufacturing defects for 1 year from the date of installation, or 1 year from shipment if the installation date is not reported.