Moxa TCC-120/120I RS-422/485 Isolated Repeater User’s Guide

Moxa TCC-120/120I user’s guide covering features, package checklist, specifications, DIP switch settings, wiring, and connection testing for the RS-422/485…


Moxa TCC-120/120I RS-422/485 Isolated Repeater User’s Guide - cover page
Brand
moxa
Category
Digital repeater
Document type
User Manual
Language
English
Pages
17
File format
PDF
File size
146 KB
Published
06 November, 2026
Updated
06 November, 2026
MD5 checksum
1990D2C3D06F948210B174CA604CD0E4

About this manual

The Moxa TCC-120 and TCC-120I are RS-422/485 isolated repeaters used to extend the transmission distance between RS-422/485 devices; the TCC-120I adds 2 KV isolation protection. This user’s guide (Eighth Edition, August 2009) introduces the products, lists their features and specifications, and explains how to install and test them.

Installation is described in four steps: setting the terminator DIP switches, attaching the 12-48 VDC power supply, wiring the RS-422/485 terminal blocks for 2-wire or 4-wire operation, and testing the connection with a console terminal program such as HyperTerminal or Moxa Terminal Emulator. The guide also covers the built-in ADDC™ data direction control, isolation and reverse power protection, and DIP switch selectable termination.

What's inside

  • Overview
  • Product Features
  • Package Checklist
  • Product Specifications
  • Product Views
  • LED Indicators
  • Hardware Installation
  • STEP 1: Set the DIP Switches
  • STEP 2: Attach the Power Supply
  • STEP 3: Wire the Terminal Block

Specifications

Baudrate50 bps to 921.6 Kbps
Isolation2 KV for both Power and Signal (TCC-120I)
Operating Temperature-20 to 60°C
Storage Temperature-20 to 85°C
Humidity5 to 95 %RH
Power Input VoltageExternal 12-48 VDC, terminal block
Power Consumption (TCC-120)3.4 W (12V x 286 mA; 24V x 143 mA; 30V x 113 mA)
Power Consumption (TCC-120I)3.68 W (12V x 390 mA; 24V x 195 mA; 30V x 156 mA)
Dimensions (W x D x H)67 x 100 x 22 mm (casing only); 90 x 100 x 22 mm including ears
Casing materialAluminum
Weight148± 5 g
Terminal block wire range#22 – #16 AWG
Regulatory ApprovalsCE, FCC (Class B)
Extended transmission distanceup to an additional 1.2 km

Frequently asked questions

What is the difference between the TCC-120 and the TCC-120I?

The TCC-120I comes with 2 KV isolation protection for both power and signal; the TCC-120 does not include this isolation rating.

What power supply does the TCC-120/120I need?

It is powered by an external 12-48 VDC power supply connected to the V+ and V- terminals on the 3-contact terminal block.

How do I enable or disable the termination resistor?

Set Switch 2 (SW2) to the ON position to enable termination and to the OFF position to disable it.

How do I select 4-wire or 2-wire mode?

Set Switch 1 (SW1) to ON for 4-wire mode and to OFF for 2-wire mode; both sets of DIP switches must be configured the same.