MAXIMATOR High-Pressure Hydraulic Power Packs Product Leaflet

MAXIMATOR high-pressure hydraulic power packs generate operating pressures up to 5,500 bar with pneumatically operated pumps for testing and clamping.


MAXIMATOR High-Pressure Hydraulic Power Packs Product Leaflet - cover page
Brand
Maximator
Category
Industrial Supply
Document type
Product Leaflet
Language
English
Pages
24
File format
PDF
File size
2.1 MB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
192B3040ED564C3F3C3A00588604DEF3

About this manual

MAXIMATOR power packs are complete hydraulic units for oil, water or aggressive media, designed to generate operating pressures up to 5,500 bar. Pressure is generated by a pneumatically operated MAXIMATOR pump connected to the existing industrial compressed-air system; an electrical connection is not necessary for pressure generation. The units include an air control unit with filter and water separator, pressure-regulating valve, pressure control gauge and manual shut-off valve.

The leaflet describes modular components, including pump models for oil, water and special liquids, air control units, air safety valves, tank sizes from 6.5 to 70 liters and manifold blocks with pressure outlets. It also lists applications such as testing, clamping, pressure vessels and hydraulic presses, and gives an example S60 power pack with a pressure ratio of 1:61 and maximum outlet pressure of 610 bar.

What's inside

  • Description and function of MAXIMATOR power packs
  • Applications for MAXIMATOR power packs
  • Advantages of the MAXIMATOR power packs
  • Components in Modular Design
  • Power Packs for Oil Service
  • MAXIMATOR large pump G series
  • MAXIMATOR standard pump S series
  • MAXIMATOR mini pump MO series

Specifications

Maximum operating pressureUp to 5,500 bar
S60 pressure ratio1:61
S60 maximum outlet pressure610 bar
S60 maximum air drive pressure10 bar
S60 maximum flow capacityApprox. 2.7 I/min
S60 approximate weight11 kg

Frequently asked questions

What pressure can MAXIMATOR power packs generate?

They are intended for generating operating pressures up to 5,500 bar.

Is an electrical connection needed to generate pressure?

No. The pressure is generated by a pneumatically operated MAXIMATOR pump, and an electric connection is not necessary.

What happens when the set final pressure is reached?

The pump stands still when the set final pressure is reached.

What is the maximum outlet pressure of the S60 power pack?

The S60 power pack has a maximum outlet pressure of 610 bar.