Marley application guide on selecting, installing and wiring vibration sensors for cooling tower motors, gearboxes, drive shafts and fans, with AC102/AC104…
This Chinese-language application guide from Marley addresses the difficulties vibration analysts face when monitoring cooling towers, where most faults occur in gearboxes mounted in hard-to-reach, hazardous locations beneath the fan. It explains that permanent accelerometers on the motor and gearbox improve safety, reliability and equipment life, and describes where to place radial and axial sensors on the drive-train components.
The guide covers sensor selection (general-purpose AC102/AC104 for vibration above 30 CPM and low-frequency AC135/AC136 for above 12 CPM), IP66-rated A2A and B2A connectors with Teflon-jacketed or armored cables, stud mounting with hole-facing tools such as the MH117-1B, junction boxes including the MX102-4C and the 12-channel SB202-12A, frequency analysis points for motors, drive shafts, gearboxes and fans, and references for typical operating limits. Page 4 lists the contents and specifications of the 12-channel cooling tower kit. This manual is written in Chinese.
| AC102-1A sensitivity | 100 mV/g +/-10% |
|---|---|
| AC102-1A frequency response | +/- 3 dB, 30-900,000 CPM (0.5 - 15,000 Hz) |
| AC102-1A dynamic range | +/- 50 g peak |
| AC102-1A temperature range | -50 to 121 °C |
| AC102-1A kit quantity | 8 |
| AC104-1A frequency response | +/- 3 dB, 30-600,000 CPM (0.5 - 10,000 Hz) |
| AC104-1A kit quantity | 4 |
| SB202-12A inputs | 3 inputs per channel, 12 channels |
| SB202-12A outputs | BNC jacks and military two-pin connectors |
| SB202-12A enclosure | NEMA 4X (IP66) |
| SB202-12A temperature range | -58 to 82 °C |
| CB111-A2A-030-Z cable | Yellow Teflon-coated cable with dual-socket military E QUAL two-pin connector, 30 ft |
The special-purpose low-frequency sensors AC135 (top outlet) and AC136 (side outlet) are for measuring vibration above 12 CPM (0.2 Hz), while the general-purpose AC102 or AC104 covers values above 30 CPM (0.5 Hz).
Up to 6 sensors on the motor and 6 on the gearbox — 4 radial and 2 axial on each. Radial sensors detect unbalance and misalignment, axial sensors detect misalignment, bearing faults and gear mesh.
IP66-rated connectors are recommended to keep out dust and water; use A2A Mil E QUAL connectors or B2A sealed entries with Teflon-jacketed or armored cables.
In Chapter 10, "Cooling Tower Mechanical Components", of the Cooling Tower Handbook; these limits are based on the cooling tower's structural design and components.