This manual provides installation instructions, safety guidelines, functional characteristics, electrical connection details, and technical specifications…
This document serves as the installation guide for the IFM PT54xx and PU54xx series of electronic pressure sensors designed for industrial applications. It covers preliminary instructions, safety warnings regarding operation and maintenance by authorized personnel only, and specific application limits based on pressure ranges.
The manual details the sensor's functionality, including current output (4...20 mA) for PT54xx models and voltage output (0...10 V) for PU54xx models. It provides step-by-step installation procedures, recommended tightening torques based on measurement range, and specific electrical connection wiring diagrams complying with DIN EN standards. This manual is written in Chinese.
The recommended tightening torque is between 30 and 50 Nm.
The recommended tightening torque is between 30 and 50 Nm.
The device requires a DC working voltage of 8.5 to 36 V.
The current output increases to between 20 and 25 mA, while the voltage output rises to 10 to 11.5 V.