This manual provides installation instructions, safety guidelines, and technical specifications for the IFM PT54/PU5480280889 electronic pressure sensor.
This document is an installation guide for the IFM electronic pressure sensors, specifically models PT54xx (current output) and PU54xx (voltage output). It covers safety warnings, application areas, functional descriptions of analog outputs, and step-by-step mechanical installation procedures including torque specifications. This manual is written in Chinese.
| Output Signal (PT54xx) | 4...20 mA |
|---|---|
| Output Signal (PU54xx) | 0...10 V |
| Operating Voltage (PT5460) | 8.5...36 DC |
| Operating Voltage (PU5460) | 16...36 DC |
| Medium Temperature Range | -40...90 °C |
| Ambient Temperature Range | -40…90 °C |
The recommended tightening torque is between 30 and 50 Nm.
The device requires a DC working voltage of 8.5 to 36 V.
The device allows for a minimum of 60 million pressure cycles.