Honeywell EM 340/341 Room Electronic Module Installation Instruction

Installation instruction for the Honeywell EM 340/341 room electronic module, a ZBUS room indicator lamp used with System 99plus nurse call systems.


Honeywell EM 340/341 Room Electronic Module Installation Instruction - cover page
Brand
Honeywell
Category
Communications equipment
Document type
Installation Guide
Language
German
Pages
2
File format
PDF
File size
281 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
5F52A0D20F26049BE60EF3A67BBFE148

About this manual

This installation instruction covers the Honeywell room electronic module EM 340/341 (Part No. 72575N1/N2/P1/P2/Z1/Z2/Z3), published by Novar GmbH, a Honeywell Company, in German, English and French. The EM 34x is a room indicator lamp designed as a ZBUS component of System 99plus and is used as a controller for patient and functional rooms without a speech function. It provides connections for call and cancellation units including calling circuit monitoring, bus lines, room components and the power supply.

The document describes mounting of the connection board and the plug-on EM 34x module, installation of the optional relay module with buzzer for door opener and local alarm functions, connection to the System 99plus ZBUS, compatibility notes and connection cable requirements. It also lists the variants: modules with and without bed bus, the connection board, and the relay module with buzzer. This manual is written in German.

What's inside

  • General information
  • Mounting connection mount and electronic module
  • Mounting relay module with buzzer
  • Installation
  • Electronic module without light casing
  • Compatibility
  • Connection cable
  • Specifications

Specifications

Operating voltage24 V DC
Power consumption84 mA @ 24 V DC
Mounting height1.5 ... 2.2 m above the floor
Connection cableTwisted pair, e.g. I-Y (St) Y, n x 2 x 0.8 mm, or system cable 89734AH/AJ

Frequently asked questions

Which systems is the EM 34x compatible with?

The EM 34x is compatible with the Clino Phon99, Opt99 (with limited functions) and 99plus systems. Firmware from V5.0R is required for the 72660C central group.

At what height should the EM 340/341 be mounted?

The connection mount is fastened at a height of 1.5 to 2.2 m above the floor, according to DIN VDE 0834-1:2000.

What cable is needed for the room and audio bus?

Each bus requires one twisted pair of wires, e.g. telecommunications cable I-Y (St) Y, n x 2 x 0.8 mm; the power supply can be carried in the same cable. Alternatively, system cable Part No. 89734AH/AJ can be used.

What happens if the installation instructions are not followed?

Claims under warranty are invalidated if damage is caused by non-compliance with the instructions, and no liability is accepted for resulting consequential loss.