Quick set-up guide for installing and configuring the Honeywell 7845i-GSM GSM communicator module, covering mounting, signal strength check, wiring…
This document provides a quick set-up guide for the Honeywell 7845i-GSM GSM communicator module. It outlines the essential steps for mounting the module, verifying cellular signal strength, connecting power and wiring, programming via web-based tools or a 7720P programmer, and registering the device with AlarmNet.
The guide includes wiring diagrams for control panel connections (12VDC, GND, ECP input/output), Ethernet port usage, battery installation, and LED indicator descriptions. Registration methods include web-based programming on AlarmNet Direct, the 7720P programmer, or calling AlarmNet Technical Assistance.
| Operating Voltage | 120V AC |
|---|---|
| DC Input | 12VDC |
| Ground | GND |
| ECP Input | Yellow wire |
| ECP Output | Green wire |
| Communication | GSM / Ethernet |
| Antenna | Internal |
| Status LEDs | Green (Status), Yellow (Message), Red (Fault) |
Plug in the AC transformer and verify that at least 3-5 bars are lit solid on the RSSI display at the mounting location.
Connect 12VDC in (red), GND (black), ECP input (yellow), and ECP output (green) to the control panel terminals.
Registration can be done via the AlarmNet Direct website, a 7720P programmer, or by calling AlarmNet Technical Assistance at 1-800-222-6525.