Service manual for the Hirschmann DS 160 Load Moment Indicator, covering system description, troubleshooting, error codes, calibration, and component…
This service manual provides detailed instructions for the maintenance and repair of the Hirschmann DS 160 Load Moment Indicator (LMI) system. The document covers the system description, which includes the central microprocessor unit, operating console, length/angle sensors, pressure transducers, and anti-two block switches. It explains how the system operates by comparing real load measurements against reference data stored in memory chips to generate overload warnings and lockout functions.
| Document Part Number | 031-300-190-142 |
|---|---|
| Revision Date | 02/16/2006 |
The LMI provides the crane operator with essential information to operate the machine within design parameters, including boom angle, working radius, rated load, and total calculated weight.
Error E01 is caused by falling below the radius range or exceeding the angle range specified in the load chart, often due to hoisting the boom too far.
When limits are reached, an overload warning signal is generated at the operator's console, and crane functions such as hoist up and boom down will be stopped.