Operating instruction manual for Hi-Force HTWP series electric driven torque wrench pumps, covering safety, setup, operation, maintenance and troubleshooting.
This manual is the operating instruction manual for the Hi-Force HTWP series of electric driven torque wrench pumps. It applies to the Hi-Force HTWP Electric range of torque pumps and contains the latest product information available at the time of publication.
The manual covers inspection upon receipt, safety precautions, declaration of incorporation/conformity, specifications, component identification, installation and setup, operation, maintenance and storage, system components and accessories, a pressure conversion table, troubleshooting and contact details.
| Maximum working pressure | 700 bar (10,000 psi) |
|---|---|
| Operating temperature range | -20 to 80 degrees C |
| HTWP2141AR specifications | 110V, 50Hz, 0.75Kw, 3.7/0.34 L/min, 60 bar changeover, 34 kg |
| HTWP2141ARH specifications | 120V, 60Hz, 0.75Kw, 4.4/0.4 L/min, 60 bar changeover, 34 kg |
| HTWP2142AR specifications | 230V, 50Hz, 0.75Kw, 3.7/0.34 L/min, 60 bar changeover, 34 kg |
| HTWP2142ARH specifications | 220V, 60Hz, 0.75Kw, 4.4/0.4 L/min, 60 bar changeover, 34 kg |
Hi-Force manufactures the HTWP Electric hydraulic pumps to operate at a maximum working pressure of 700 bar (10,000 psi).
The pump must never be inverted or laid on its side in use, transport or storage.
The pump is not ATEX rated and is not suitable for work in explosive environments.
Steel toe-cap safety shoes, safety glasses/visor, ear protection and protective gloves should be worn at all times.