Hi-Force TLA50 Series ToughLift Air Driven Jacking System OM-TLA50-01 Operating Instruction Manual

The Hi-Force TLA50 series Air Driven ToughLift Jacking Systems are designed to be an easy to operate, all-in-one air-powered jacking system.


Hi-Force TLA50 Series ToughLift Air Driven Jacking System OM-TLA50-01 Operating Instruction Manual - cover page
Brand
Hi-Force
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
21
File format
PDF
File size
2.3 MB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
96255AB33616DC29F46BE9388C6122B2

About this manual

The Hi-Force TLA50 Series ToughLift Jacking System is an air-driven, mobile jacking unit with an adjustable handle and a ‘V-Lift’ system for positioning the lifting cylinder under the load. It is available with a 254 mm or 355 mm stroke and has a lifting capacity of 50 tonnes at a maximum operating pressure of 700 bar (10,000 psi).

This operating instruction manual applies to the TLA50 series only. It covers inspection upon receipt, safety precautions, declaration of incorporation/conformity, component identification, installation/setup, operation, lifting and transport, maintenance and storage, specifications, system components/accessories, and troubleshooting.

What's inside

  • Inspection upon Receipt
  • Safety Precautions
  • Component Identification
  • Installation/Setup
  • Operation
  • Lifting and Transport
  • Maintenance and Storage
  • Specifications
  • System Components/Accessories
  • Troubleshooting

Specifications

Lifting capacity50 tonnes
Maximum operating pressure700 bar (10,000 psi)
Stroke length options254 mm or 355 mm
Power supply6-bar air driven
Pump2-stage pump; stage 1 0–60 bar at 3.9 l/min; stage 2 60–700 bar at 0.36 l/min
TLA5010 specifications50 tonnes capacity; 254 mm stroke; 160 kg weight; 680 mm max additional stack
TLA5014 specifications50 tonnes capacity; 355 mm stroke; 170 kg weight; 680 mm max additional stack

Frequently asked questions

What is the lifting capacity of the TLA50 series?

It has a lifting capacity of 50 tonnes at a maximum operating pressure of 700 bar (10,000 psi).

What stroke lengths are available for the TLA50 series?

The units are available with a 254 mm or 355 mm stroke length.

What should I do if the product is damaged during shipping?

Notify the courier immediately and refrain from putting the product into service.

How should a lifted load be supported?

Once lifted, all loads should be supported using rigid mechanical structures.