This manual provides operation and maintenance instructions for Hi-Force HEP series electric pumps, covering models HEP1, HEP103, HEP2, HEP3, and HEP5.
This document serves as the operation manual for the Hi-Force HEP series of electric pumps, specifically designed for operating high-pressure hydraulic cylinders and tools up to 700 bar. It covers safety precautions, operational procedures, and maintenance guidelines to ensure safe and correct usage. This manual is written in Chinese.
| Maximum Working Pressure | 700 bar (10,000 psi) |
|---|---|
| Recommended Hydraulic Oil | Hi-Force HFO32 or HFO46 |
| Oil Change Interval | Every 300 working hours |
| Motor Power (HEP1 Series) | 0.35kW |
| Motor Power (HEP103 Series) | 0.45 kW |
Operators must wear safety shoes, glasses, helmets, and gloves.
No, modifications and installation of other parts are not allowed without factory permission.
The hydraulic oil should be completely replaced after approximately 300 working hours.