HEIDENHAIN ROC 425 and ROQ 437 absolute rotary encoders with EnDat 2.2 for safety-related applications.
This Product Information document covers HEIDENHAIN ROC 425 singleturn and ROQ 437 multiturn absolute rotary encoders for absolute position measurement with safe singleturn information. It describes synchro-flange and clamping-flange versions with an EnDat 2.2 interface.
The document lists functional safety, electrical, mechanical, and environmental specifications, plus electrical connection, mounting, and required mating dimensions.
| Interface | EnDat 2.2 |
|---|---|
| Position values per revolution | 33 554 432 (25 bits) |
| Revolutions | 4096 (12 bits) |
| Calculation time / clock frequency | ≤ 7 μs / ≤ 16 MHz |
| System accuracy | ±20″ |
| Functional safety | SIL 2 as per EN 61508; Category 3, PL d according to EN ISO 13849-1:2015 |
| PFH | ≤ 10 · 10^-9 |
| Safe position | Encoder ±1.76° (SM = 0.7°); mechanical coupling ±0° |
| Cable length | ≤ 100 m at ≤ 8 MHz; ≤ 20 m at ≤ 16 MHz |
| Supply voltage | DC 3.6 V to 14 V |
| Power consumption, maximum (ROC 425) | ≤ 600 mW at 3.6 V; ≤ 700 mW at 14 V |
| Power consumption, maximum (ROQ 437) | ≤ 700 mW at 3.6 V; ≤ 800 mW at 14 V |
| Current consumption, typical | 80 mA at 5 V (ROC 425); 95 mA at 5 V (ROQ 437) |
| Shaft (synchro flange) | 92A solid shaft, Ø 6 mm with flat |
| Shaft (clamping flange) | 03D solid shaft, Ø 10 mm with flat |
| Shaft speed (ROC 425) | ≤ 15 000 rpm |
| Starting torque, typical | 0.01 Nm at 20 °C |
| Moment of inertia of rotor | 2.9 · 10^-6 kgm^2 |
| Angular acceleration of rotor | ≤ 1 · 10^5 rad/s^2 |
| Shaft load | Axial ≤ 40 N; radial ≤ 60 N at shaft end |
| Vibration | 55 Hz to 2000 Hz |
| Shock | ≤ 2000 m/s^2 |
| Minimum operating temperature | Flange socket or fixed cable: -40 °C; moving cable: -10 °C |
| Maximum operating temperature | 100 °C |
| Trigger threshold for temperature exceedance error message | 125 °C in the scanning ASIC |
| Relative humidity | ≤ 93 % |
| Protection | Housing IP67; shaft inlet IP64 |
| Mass | ≤ 0.3 kg |
| Electrical connection | 8-pin M12 radial or axial flange socket, or 1 m PUR cable with 8-pin M12 coupling |
They use the EnDat 2.2 interface.
The supply voltage is DC 3.6 V to 14 V.
SIL 2 as per EN 61508 and Category 3, PL d according to EN ISO 13849-1:2015.
The maximum operating temperature is 100 °C.