Installation and operating manual for Harman Trident SF160 and SF260 solid-fuel boilers, covering setup, venting, plumbing, operation, maintenance, and service.
This manual covers the Harman Trident SF160 and SF260 boilers, including packing list, installation, aquastat, wiring, venting, plumbing, operating instructions, fuel loading, ash shaking, safety tips, maintenance, specifications, warranty, service log, and service parts.
It states that the boiler is tested and approved for solid fuel only (wood, coal), must not be installed closer than 18 inches (457 mm) to combustible material, and must be vented to an approved chimney with a minimum recommended height of 16 ft (4.8 m) above the flue collar.
| Approved fuels | Solid fuel only (wood, coal) |
|---|---|
| Clearance to combustibles | Not closer than 18 inches (457 mm) |
| Minimum chimney height | 16 ft (4.8 m) above flue collar |
| Flue size | 8 x 8 in. or equivalent, up to 8 x 12 in. |
| Pressure relief valve | 30 psi |
The boiler is tested and approved for solid fuel only (wood, coal); burning any other type of fuel voids the warranty.
It should not be installed closer than 18 inches (457 mm) to any combustible material.
The minimum recommended height is 16 ft (4.8 m) above the flue collar.
The supplied pressure relief valve is rated at 30 psi.