Harman SF1500A and SF2500A hot air furnace installation and operating manual covering clearances, venting, wiring, operation, maintenance, and service parts.
The Harman SF1500A and SF2500A are solid-fuel hot air furnaces. This manual gives installation and operating directions, including required clearances, chimney and venting guidelines, blower and filter box mounting, and wiring of the draft control, fan control, thermostat, relay, and junction box.
Safety notices warn that improper installation can cause a house fire and that the units are approved for wood or coal only. The manual also lists packing contents and covers operation, safety tips, chimney troubleshooting, maintenance, specifications, coil installation, service parts, and warranty.
| Side and rear clearance to combustibles | 24 in. at sides; 30 in. at rear |
|---|---|
| Chimney minimum size | 8 in. x 8 in. |
| Chimney minimum height | 16 ft. |
| Draft requirement | 0.06 in. water column |
| Maximum stovepipe length | 8 ft. |
| Hot air plenum clearance to ceiling | 2 in. minimum |
| Power supply line | 120 V |
| Thermostat wire gauge | 22 gauge or thicker |
The units are tested and approved for solid fuel only, specifically wood and coal.
Keep at least 24 inches at the sides and 30 inches from the rear to combustible materials.
The chimney must provide a draft reading of at least .06 inches water column on a draft meter.
The manual recommends installation by a qualified installer.
The fan control should be installed 12 to 18 inches above the top of the furnace.