Installation manual for the Harman PF-120 pellet furnace, covering safety, clearances, venting, setup, electrical power, and specifications.
This installation manual covers the Harman PF-120 pellet furnace. It includes safety information, clearances, venting, appliance setup, electrical power, and reference materials. The manual states the appliance is tested and approved for wood pellet fuel only and lists specifications such as 120 VAC power, 5 mm ceramic glass, and a 160 lb hopper capacity.
Sections include an installation standard work checklist, appliance certification, tools and supplies, clearances to combustibles, floor protection, termination and vent information, return air filter box, blower assembly, firebrick, wall control, duct system installation, adding air conditioning, fan/high limit control, and wiring diagram.
| Electrical rating | 120 VAC, 60 Hz; 9.2 A max start, 7.5 A normal operation |
|---|---|
| Glass | 5 mm ceramic glass |
| BTU output | 8,000 - 120,000 / hr |
| Hopper capacity | 160 lbs |
| Fuel | Wood pellets |
| Shipping weight | 580 lbs |
| Particulate emissions rating | N/A |
| Heating capacity | N/A |
| Mobile home approval | Approved (US only) with outside combustion air inlet |
It is tested and approved for wood pellet fuel only.
It requires 120 VAC, 60 Hz, with 9.2 A maximum start and 7.5 A normal operation.
It is equipped with 5 mm ceramic glass, and replacement glass must also be 5 mm ceramic glass.
Yes, in the US, when it is not installed in a sleeping room and an outside combustion air inlet is provided.