The Growatt ShineLink-X user manual explains how to install and configure this PV datalogger for remote monitoring through LAN, mobile app, and web server.
The Growatt ShineLink-X is a datalogger compatible with all on-grid inverters with a USB port. It enables remote monitoring and maintenance of photovoltaic systems through a LAN cable and supports mobile APP and server web page monitoring.
The manual covers product overview, appearance, system diagram, installation and configuration, LED status descriptions, button functions, quick troubleshooting, and technical specifications. This manual is written in Chinese.
| Dimensions (L/W/H) | 105mm/85mm/26mm |
|---|---|
| Weight | 103g |
| Protection degree | IP30 |
| Nominal voltage | 5V(±5%) |
| Nominal current | 1A |
| Typical power consumption | 3W |
| Operating temperature | -20℃ ~ + 65℃ |
| Storage temperature | -40℃ ~ + 70℃ |
| Relative humidity | 5–95% RH |
Rotate the USB cover counterclockwise, set the locker triangle to the front center, connect to the USB port, press the locker, and rotate clockwise until tight.
It means a loose connection, so re-plug the datalogger.
Press and hold the button for 6 seconds until the white light is on.
The maximum RF wireless communication distance is 120 meters in open distance.