Growatt series solar inverters are used to convert the DC power generated by solar module panels into AC power and deliver it to the grid in a three-phase manner.
This manual covers the Growatt MID TL3-X2 series grid-tied solar inverters, models MID 20KTL3-X2, MID 25KTL3-X2, and MID 30KTL3-X2. It provides product information, safety instructions, and installation and operating guidance, and describes the inverter's role in a grid-tied PV system between the solar modules and the utility grid.
The document explains unpacking inspection, wall-mount installation and required clearances, AC and DC side wiring, grounding, and signal line connection. It also covers commissioning, operating modes, the OLED display and touch-button settings (protection voltage level, language, COM address, date and time), RS485 and USB-A communication, start-up and shutdown, troubleshooting, specifications, and torque values. This manual is written in Chinese.
| Input voltage range | 160V-1000V |
|---|---|
| Maximum DC input voltage | 1100V |
| Maximum efficiency | 98.75% |
| Protection rating | IP66 |
| Weight | 24 kg (MID 30KTL3-X2) |
| Dimensions | 528 x 415 x 225 mm (MID 30KTL3-X2) |
| Operating ambient temperature | -25 to 60 degC |
| Storage temperature | -25 to +60 degC |
| Storage relative humidity | below 90% |
| Recommended AC output breaker | 40A/220V (MID 20KTL3-X2), 50A/220V (MID 25KTL3-X2), 60A/220V (MID 30KTL3-X2) |
| Maximum power point trackers | 2 independent trackers |
| Communication | RS485 |
The DC input voltage must never exceed 1100V; higher input voltage may permanently damage the inverter, and the warranty does not apply in that case.
Yes. The inverter has an IP66 protection rating and can be installed either indoors or outdoors.
If a leakage protection switch must be installed between the inverter output and the grid, use a B-type switch rated at 300mA or above.
Minimum clearances are 30 cm above, 50 cm below, 30 cm on each side, and 30 cm in front.