About this manual

The Fast Rack 4.0 Solar Panel Mounting System Installation Manual describes a mounting system developed to flat mount solar panels to a pitched metal or shingle rooftop. It covers features, system components, required tools, fasteners, and a racking system overview.

The step-by-step guide covers overall mount layout, hanger bolt and L-bracket installation, rail preparation and splicing, rail installation, end and mid clamp installation, an Enphase inverter option, grounding components, solar panel installation, and flashing installation. The manual also notes installer/owner responsibility for local building and electrical codes, structural verification, and fall arrest equipment.

What's inside

  • Introduction
  • Features
  • System components
  • Tools required
  • Fasteners
  • Racking System Overview
  • Step By Step Installation Guide
  • Grounding components installation
  • Solar panel installation
  • Flashing installation

Specifications

Adjustable mounting foot height+/- 1 in
Rail overhang from panel side2 in or less
Panel row gap1/4 in (6 mm) to 3/8 in (10 mm)
End clamp tightening torque15 ft lb (21 Nm)

Frequently asked questions

What type of rooftop is the Fast Rack system designed for?

It is developed to flat mount solar panels to a pitched metal or shingle rooftop.

What torque should the end clamps be tightened to?

End clamps should be tightened to 15 ft lb (21 Nm) using a torque wrench.

What gap is required between vertical rows of solar panels?

A 1/4 in (6 mm) to 3/8 in (10 mm) gap should be provided between vertical rows.