Endress+Hauser PROline Promag 23 H Electromagnetic Flow Measuring System Technical Information

Endress+Hauser PROline Promag 23 H is a two-wire, loop-powered electromagnetic flow measuring system for hygiene, food, beverage and process applications.


Endress+Hauser PROline Promag 23 H Electromagnetic Flow Measuring System Technical Information - cover page
Brand
Endress+Hauser
Category
flow transmitter
Document type
Product Leaflet
Language
English
Pages
30
File format
PDF
File size
1.1 MB
Published
07 November, 2026
Updated
07 November, 2026
MD5 checksum
143EF60DA82849B8B7E989078173BD7E

About this manual

The Endress+Hauser PROline Promag 23 H is a two-wire, loop-powered electromagnetic flow measuring system designed for hygiene, food and beverage or process applications. It measures all fluids with a minimum conductivity of 50 µS/cm, such as beverages, salt solutions, acids and alkalis, and is available in nominal diameters DN 2 to 100 with a PFA lining.

The system consists of a Promag 23 transmitter and a Promag H sensor in a compact version with a robust IP 67 field housing. It offers a current output 4...20 mA with HART communication, optional frequency/pulse/status outputs, and intrinsically safe Ex ia protection for zone 1 installation. Measuring accuracy is ± 0.5% of reading, with repeatability of ± 0.25% of reading.

What's inside

  • Features and benefits
  • Application
  • Function and system design
  • Output
  • Power supply
  • Installation conditions
  • Measuring accuracy
  • Potential equalisation
  • Orientation

Specifications

Nominal diameterDN 2...100
Lining materialPFA
Cleaning temperatureup to +150 °C
Protection ratingIP 67
Measuring accuracy± 0.5% o.r. ± 4 mm/s
Output signal4...20 mA
Supply voltage non-Ex12...30 V DC
CommunicationHART
Measuring range0.01...10 m/s
Repeatability± 0.25% o.r. ± 2 mm/s

Frequently asked questions

What is the measuring accuracy of the Promag 23 H?

The maximum measured error is ± 0.5% of reading plus 4 mm/s, with repeatability of ± 0.25% of reading plus 2 mm/s.

What supply voltage does the transmitter use?

Non-Ex environments use 12...30 V DC, while Ex environments use 13.9...30 V DC.

Is HART communication included?

Yes, HART communication is standard on the device.

What nominal diameters are available?

The flow measuring system is available in nominal diameters DN 2 to 100.

Download PDF (1.1 MB)

More Endress+Hauser Manuals


View all Endress+Hauser manuals →