User manual and installation instructions for the Electro-Steam LB-40(C) thru LB-60(C) portable steam cleaner, covering setup, operation and maintenance.
The Electro-Steam LB-40(C) thru LB-60(C) portable steam cleaner is described as a high-pressure chamber filled with water, heated by one or more submerged resistance electric heating elements. Automatic controls maintain the pre-set operating pressure and water level; safety features include automatic low-water cutoff, dual pressure controls, a safety valve, and a visible water level gauge. The generators are built according to the A.S.M.E. Miniature Boiler Code and are individually inspected and stamped by an Authorized National Board Insurance Inspector.
The user manual and installation instructions cover placing the unit on a level floor, attaching the solution bucket, electrical and water connections, steam outlet and drain routing. It explains startup and sequence of events, cleaning and maintenance procedures, pressure control settings, calculations and data sheets, parts legends, and control and heater wiring schematics. An optional Solution Mixer installation for the HydroMinder Model 511 is also included.
| Maximum ambient temperature around unit | 105 °F |
|---|---|
| Water supply purity | Not to exceed 26,000 OHMS per CM |
| Water supply temperature range | 32°F - 140°F or 0°C - 60°C |
| Water supply pressure range | 20 PSI - 150 PSI |
| Pressure control set point | 85 PSI |
The manual states a water supply pressure range of 20 PSI to 150 PSI.
The ambient temperature around the unit must not exceed 105 °F.
The label instructs replacing the glass every six months.
Pressure rises until it reaches 85 PSI; the control then disengages the contactors and pressure drops about 5-8 PSI before they reengage.