The Electro-Steam LB-40(C) thru LB-60(C) portable steam cleaner is described as a high-pressure chamber filled with water, heated by one or more submerged resistance electric heating elements. Automatic controls maintain the pre-set operating pressure and water level; safety features include automatic low-water cutoff, dual pressure controls, a safety valve, and a visible water level gauge. The generators are built according to the A.S.M.E. Miniature Boiler Code and are individually inspected and stamped by an Authorized National Board Insurance Inspector.

The user manual and installation instructions cover placing the unit on a level floor, attaching the solution bucket, electrical and water connections, steam outlet and drain routing. It explains startup and sequence of events, cleaning and maintenance procedures, pressure control settings, calculations and data sheets, parts legends, and control and heater wiring schematics. An optional Solution Mixer installation for the HydroMinder Model 511 is also included.

What's inside

  • Installation Instructions
  • Solution Mixer Installation
  • Operation & Sequence of Events
  • Cleaning & Maintenance
  • Manual Blow Down
  • Cleaning Water Level Probes
  • Cleaning or Replacing Heaters
  • Replacing Glass Gauge and Rubber Washers
  • Setting the Pressure Controls
  • Drawings & Wiring Schematics

Specifications

Maximum ambient temperature around unit105 °F
Water supply purityNot to exceed 26,000 OHMS per CM
Water supply temperature range32°F - 140°F or 0°C - 60°C
Water supply pressure range20 PSI - 150 PSI
Pressure control set point85 PSI

Frequently asked questions

What water pressure range does the steam generator require?

The manual states a water supply pressure range of 20 PSI to 150 PSI.

What is the maximum ambient temperature around the unit?

The ambient temperature around the unit must not exceed 105 °F.

How often should the glass gauge be replaced?

The label instructs replacing the glass every six months.

What pressure does the control use to cycle the contactors?

Pressure rises until it reaches 85 PSI; the control then disengages the contactors and pressure drops about 5-8 PSI before they reengage.