This file is the user manual of the electric steam generator LG-10~LG-40 of Electro-Steam Generator Corp. It mainly introduces the working principle, safety precautions and daily maintenance of the electric steam generator
This document serves as the User, Installation, and Maintenance Manual for the Electro-Steam LG-Series steam generators, covering models LG-10, LG-15, LG-20, LG-25, LG-30, and LG-40. The unit is a high-pressure chamber filled with water heated by submerged resistance elements, designed to maintain preset operating pressure and water levels automatically. It complies with ASME Boiler and Pressure Vessel Code Section I.
| Power Range | 10-40kW |
|---|---|
| Ambient Temperature Limit | 105°F |
| Water Purity Requirement | NOT to exceed 26,000 OHMS per CM |
| Water Temperature Range | 32°F – 140°F or 0°C – 60 °C |
| Water Supply Pressure Range | 20PSI – 150PSI |
| Safety Valve Type | Overpressure Safety Relief Valve |
In normal water areas, it should be done once a week; in bad water areas, once a day.
In normal water areas, twice a year; in bad water areas, 3-4 times a year.
The ambient temperature around the unit must not exceed 105°F.