This is a manual of installation and use of S.S. LG-10 to LG-30 model steam boilers
This manual provides comprehensive installation and operation instructions for the Electro-Steam S.S. LG-10 through LG-30 steam generators. It details the unit's design, which consists of a high-pressure chamber heated by submerged resistance elements, and outlines the sequence of events during startup and operation. Important safety warnings regarding high voltage, hot water, and steam pressure are emphasized throughout the document.
| Ambient Temperature Limit | 105°F (40°C) |
|---|---|
| Water Purity Range | 1 – 5.5 MEG OHM per CM |
| Water Temperature Range | 32 – 140°F (0 – 60°C) |
| Water Pressure Range | 20 – 80PSI |
| Max Flow Rate | 2 GAL/MIN |
| Blow Down Frequency | At least twice a month |
| Probe Cleaning Frequency | At least twice a year |
A manual blow down should be performed at least twice a month to extend the life of the generator.
The best time to clean the probes is before the generator is turned on, while it is still cool.
You must connect a D.I. or R.O. purity water line to the Water Solenoid.
The ambient temperature around the unit must not exceed 105°F (40°C).