This document is about Electro-Steam steam generator user manual and installation instructions.
The Electro-Steam S.S. LG-10 thru LG-30 is a steam generator whose design consists of a high-pressure chamber filled with water heated by one or more submerged resistance-type electric heating elements. Automatic controls maintain the pre-set operating pressure and water level, and safety features include automatic low-water cutoff, dual pressure controls, a safety valve, and a visible water level gauge.
This user manual and installation instructions covers installation, operation and sequence of events, cleaning and maintenance, calculations and tables, and drawings and wiring schematics for the LG-Series. It includes procedures for manual blow down, cleaning water level probes, cleaning or replacing heaters, replacing the glass gauge and packings, chamber chemical/acid treatment, and setting the pressure switches.
| Water purity range | 1 – 5.5 megohm per cm |
|---|---|
| Water supply temperature range | 32 – 140°F (0 – 60°C) |
| Water supply pressure range | 20 – 80 PSI |
| Maximum water flow rate | 2 gal/min |
| Maximum ambient temperature around unit | 105°F (40°C) |
The water supply pressure range is 20–80 PSI.
A manual blow down should be done at least twice a month, preferably while the generator is still hot after running.
The probe rods should be cleaned at least twice a year, preferably before the generator is turned on while it is still cool.
Safety features include dual pressure controls, a safety valve, and a visible water level gauge.