This file is about the S.S. LB-100 thru LB-240 High Pressure Double Stack w/ Mercoid boiler, including usage and installation instructions.
This manual covers the installation, operation, and maintenance of the S.S. Double Stack LB-100 through LB-240 high pressure steam generators manufactured by Electro-Steam Generator Corp. The unit is a stainless steel package designed for pressures up to 100 PSI, utilizing submerged resistance heating elements and automatic controls for water level and pressure management.
| Pressure Range | 0-100 LBS. PSI |
|---|---|
| Water Purity Requirement | AT LEAST 1 MEG/OHM per CM |
| Water Temperature Range | 32°F – 140°F or 0°C – 60°C |
| Water Supply Pressure Range | 20PSI – 150PSI |
| Maximum Ambient Temperature | 104°F or 40°C |
| Safety Valve Discharge Requirement | NO PVC |
The Seismic Sight Glass and glass packings must be replaced every six months.
A manual blow down should be done at least twice a month to extend the life of the generator.
Heaters must be taken out and inspected at least once a year if chemical treatments are not regularly done.
The safety valve must route to a high temperature drain made of materials other than PVC.