DYNISCO MDA/LDA/TDA Series Pressure Sensor User Manual

DYNISCO MDA/LDA/TDA Series pressure sensor user manual covering safety, technical data, operation, installation, maintenance, accessories and troubleshooting.


DYNISCO MDA/LDA/TDA Series Pressure Sensor User Manual - cover page
Brand
Dynisco
Category
sensor
Document type
User Manual
Language
Italian
Pages
31
File format
PDF
File size
546 KB
Published
19 November, 2026
Updated
19 November, 2026
MD5 checksum
9D5188216A06A0838BAD134736DC0B74

About this manual

This Italian user manual covers the DYNISCO MDA/LDA/TDA Series pressure sensors for high temperatures and high pressures, including models MDA 420/460/435/467, PT 420/460, TDA 432/463, and LDA 415. It provides general notes, safety rules, technical data, operation, transport and packaging, mounting, commissioning, maintenance, accessories, troubleshooting, and conformity declarations.

The sensors measure polymer melt pressure and contain an integrated signal amplifier. The manual lists ordering specifications, pressure ranges, electrical data, temperature influence, materials, protection class, weight, dimensions, accessory part numbers, and a troubleshooting table with possible causes and solutions. This manual is written in Italian.

What's inside

  • Note generali
  • Norme sulla sicurezza
  • Dati tecnici
  • Funzionamento
  • Montaggio
  • Messa in funzione
  • Manutenzione
  • Accessori
  • Soluzione dei problemi
  • Riparazioni / smaltimento

Specifications

Accuracy (xDA4 2x)± 0,5 % del valore finale
Reproducibility (xDA4 2x)± 0,1 % del valore finale
Max housing temperature+120 °C
Max diaphragm temperature400 °C
Weight0,6 kg
Protection class (housing without plug)IP54
Output signal3,33 mV/V ± 2 %
Supply voltage10 VDC recommended

Frequently asked questions

What is the maximum diaphragm temperature?

The maximum admitted diaphragm temperature is 400 °C.

What is the weight of the pressure transducer?

The weight is 0,6 kg.

What carrier does the sensor contain?

It contains a limited quantity of mercury (Hg) as a carrier.

What is the output signal?

The output signal is 3,33 mV/V ± 2 %.

Download PDF (546 KB)