Dynisco PT415 D pressure sensor operating manual for installation, wiring, calibration, operation, and maintenance.
The Dynisco PT415 D operating manual describes installation, wiring, operation, calibration, and repair information for a pressure sensor designed for measurements up to 750F (400C). It covers mounting-hole preparation, transducer installation, torque, wiring, start-up, and warranty contact details.
The manual also notes that the PT415 D uses a four-arm, 350 ohm Wheatstone bridge strain gage and a NaK fill, and that these transducers are not suitable for hazardous-area classifications.
| Operating temperature | up to 750F (400C) |
|---|---|
| Strain gage | four arm, 350 ohm Wheatstone bridge strain gage |
| Mounting hole | 1/2-20 UNF |
| Adequate mounting torque | 100 inch-pounds |
| Maximum recommended torque | 500 inch-pounds |
| Wiring | six-wire shielded cable integral to the transducer |
| NaK fill volume | less than 0.004 cubic inches |
| Hazardous area suitability | not suitable for hazardous area classification |
It provides pressure measurements up to 750F (400C).
An adequate seal should be obtained with 100 inch-pounds of mounting torque.
No, it is not suitable for areas with a hazardous area classification.
It uses a six-wire shielded cable integral to the transducer.