Describes the features and usage of the DYN-X-V series voltage output amplified series melt pressure transmitters
This operating manual from Dynisco covers the DYN-X-V Series and related 0–10 Vdc and 0–5 Vdc voltage output amplified melt pressure transmitters. It explains correct use, safety notes, technical data, transport, installation, commissioning, maintenance, accessories, troubleshooting and the CE Declaration of Conformity.
The transmitters are intended to measure pressure in plastic melt as part of a larger system and contain an integral signal amplifier. The manual states media temperatures up to 400°C, with oil-filled XPT41X5/XPT41X6 versions specified to 275°C continuous use and NaK-filled versions (option codes B628 and B171) to 518°C. It also warns about mercury, NaK and food-grade oil fill media and requires the protective cap to remain on during transport and storage.
| Accuracy (DYN-X-V, DYN-X-V-TC, PT4655XL, PT4656XL) | ±1.0% of full scale (0-500 psi and above) |
|---|---|
| Accuracy (PT4605, PT4606, PT4625, PT4626, TPT4635, TPT4636, PT4185, PT4195, PT4186, PT4196, TPT4195, TPT4196, EPR5, EPR6, EPR5-TC, EPR6-TC, PT4675, PT4676) | ±0.50% of full scale (0-500 psi and above) |
| Maximum media temperature | Up to 400°C |
| Oil-filled transmitter temperature | 275°C continuous use |
| NaK-filled transmitter temperature | 518°C |
It covers the listed 0–10 Vdc transmitters, including DYN-X-V and DYN-X-V-TC, and the listed 0–5 Vdc transmitters, including PT4605 and PT4655XL.
It measures pressure in plastic melt as part of an overall larger system and contains an integral signal amplifier.
Never transport or store the PT without the protective cap; remove the cap shortly before installation.
DYN-X-V, DYN-X-V-TC, PT4655XL and PT4656XL have ±1.0% of full scale accuracy for 0-500 psi and above.