Installation and safety instructions for the CP CP-4030 controller, including motor wiring diagrams and configuration settings.
This document provides installation and safety instructions for the CP CP-4030 electronic controller. It covers the main components of the central unit and includes wiring diagrams for single-phase and three-phase electric motors.
The manual also shows how to connect limit switches, magnetic sensors, photocells, magnetic locks, courtesy lights, sirens, and gate open indicators. It explains terminal configuration, jumper SW settings, and how to adjust the timer and pause trimpots for gate and barrier operating modes. This manual is written in Portuguese.
| Input voltage | 90Vac-240Vac |
|---|---|
| Fuse | 10A |
| Voltage selector | 220/380 Volts |
| Timer range | 3 seconds to 127 seconds |
| Pause range | 8 seconds to 127 seconds |
| Photocell max current | 400mA |
| Aux lamp max power | 300W |
For single-phase motors, swap wires “W” and “V”, “3” and “2”, or “White” and “Orange”. For three-phase motors, swap “W/Y” and “V/X” or “3/5” and “2/4”.
No, a capacitor must not be used for three-phase connections.
No, the auxiliary output is only a switch and does not have voltage.
Yes, grounding is mandatory.