COSEL DPG500/DPG750 DC Power Supply Bus Converter Power Module Datasheet

COSEL DPG500/DPG750 DC power supply bus converter power module datasheet with input, output, efficiency, protection, environment and safety specifications.


COSEL DPG500/DPG750 DC Power Supply Bus Converter Power Module Datasheet - cover page
Brand
Cosel
Category
AC-DC Power
Document type
Datasheet
Language
English
Pages
3
File format
PDF
File size
368 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
25C30D0387D4F5D5372EF55DACBA5F0F

About this manual

COSEL DPG500 and DPG750 are DC power supply bus converter power modules. The document lists ordering information, specifications, external view dimensions, and performance data for both models.

Specifications include AC input ranges, 360 V DC output, model-dependent output wattage, efficiency, power factor, protection, isolation, environmental limits, safety approvals, case size, and conduction cooling.

What's inside

  • Ordering information
  • SPECIFICATIONS
  • External view
  • Performance data
  • OUTPUT VOLTAGE FOR INPUT
  • STATIC CHARACTERISTICS
  • HARMONIC CURRENT

Specifications

Input voltageAC85-264 V or AC170-264 V, 1 phase
Maximum output wattage300/500/500/750 W depending on model and input
DC output voltage360 V
Input current3.47/2.86/5.72/4.24 A typ
Frequency50/60 Hz (47-63 Hz)
Efficiency92/95/93/96 % typ
Power factor0.96/0.93 typ
Leakage current0.75 mA max
Voltage accuracy±2%
Overvoltage protectionDC400-450 V
ENA signalOpen-drain output, max sink 10 mA, max voltage 35 V
IsolationInput-output non-isolated; input/output-FG AC2800 V 1 min
Operating temperature, humidity and altitude-40 to +100 C on aluminum base plate, 20-95% RH non-condensing, 3000 m max
Storage temperature, humidity and altitude-40 to +100 C, 20-95% RH non-condensing, 9000 m max
Vibration10-55 Hz, 49.0 m/s2 (5G), 3 min period, 60 min each axis
Impact196.1 m/s2 (20G), 11 ms, once each axis
Safety agency approvalsUL60950-1, C-UL, EN60950-1, EN50178; complies with DEN-AN and IEC60950-1
Harmonic attenuatorComplies with IEC61000-3-2
Case size and weight58.4 x 12.7 x 61 mm, 100 g max
Cooling methodConduction cooling

Frequently asked questions

What is the DC output voltage?

360 V; when input voltage is more than 240 V, output voltage becomes proportional to input voltage.

Is parallel operation possible?

No, parallel operation is impossible.

What cooling method is used?

Conduction cooling, such as heat radiation from the aluminum base plate to the attached heat sink.

What safety approvals are listed?

UL60950-1, C-UL, EN60950-1, EN50178, and compliance with DEN-AN and IEC60950-1.